Network route planning
Drain routes mapped against the site plan and building layout

Hawalli
Sewer network in Bidaa links bathrooms from old villas and apartments in a coastal district toward treatment or the government boundary. We establish the natural grade of the area and design the line with slope that suits the coastal soil, then test it with full flow.
Bidaa near Salmiya holds a mix of residential villas and apartment blocks built in different decades. The soil here is sandy with salt layers and high groundwater close to the surface. We choose pipes rated for salt corrosion, raise the trench level slightly to avoid brackish groundwater, and backfill with sifted material instead of raw sand.
Bidaa is in Hawalli near the Salmiya seafront, a coastal area where sandy soil and groundwater are saturated with salt.
Buried lines are inspected with a detection camera to ensure brackish water does not seep into the pipes.
Drain routes mapped against the site plan and building layout
Pipes set at calculated gradients on compacted sand bedding to prevent sagging
Chambers built at every change of direction for future maintenance access
Network pressure-tested before backfilling to confirm all joints are sealed
In-line filming reveals any deflection or cracked joint before trench closure
Drain networks for new construction and building extensions to the same standard
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, high moisture and salt accelerate corrosion of standard pipes. We use enhanced-grade pipes and seal every joint with graphite to prevent brackish leakage and oxidation.
We raise the trench depth slightly and use fully sealed pipes. If the water table remains too high we consult the engineer to design a temporary sump pit during installation.