Isolation valves
Repair or replace main and branch isolation valves that no longer shut fully.

Ahmadi
Valve repair at Zour focuses on large isolation valves in condensate steam and chilled-water lines for turbines. We disassemble, inspect the seat and ball for thermal cracking, mineral scaling and deposits, run dye penetrant on the seat and replace the valve if cracking runs deep.
Zour power station runs steam and chilled-water in high-pressure, high-temperature closed loops, and isolation valves in these circuits endure extreme temperature swings. Hot then cold water causes rapid expansion and contraction in the valve body, opening tiny cracks in the seat. We check seat integrity with fluorescent dye before reassembly and record pressure and temperature readings.
Zour lies in Ahmadi governorate and houses a power-generation plant relying on condensate and complex cooling cycles.
Every valve undergoes dye penetrant inspection before handover because fine thermal cracks are invisible to the eye.
Repair or replace main and branch isolation valves that no longer shut fully.
Fix stiff or leaking ball valves caused by scale deposits around the ball seat.
Repair broken or corroded gate valve stems common in older Kuwaiti homes.
Adjust or replace pressure-reducing valves causing fluctuating supply pressure.
Repair float valves in ground and roof tanks that overflow or fail to shut off.
Replace failed check valves that allow backflow in pump and tank feed lines.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
If the crack is shallow and under three inches we might grind it carefully and clean it. But in high-pressure steam lines we replace the valve because any crack will widen quickly under thermal cycling.
Usually four to six hours including removal, inspection, dye testing and reassembly. If cracks are found we swap the whole valve, which may take a full day.