Acoustic pipe listening
Sensitive sensor picks up leak noise through tiles and plaster

Jahra
Leak detection in Naeem relies on measuring moisture in foundations and external walls where rainwater and old well water seep. We trace water path from exterior to interior precisely before cutting beneath the floor.
Naeem houses are older, built over old artesian wells, and groundwater rises in winter to penetrate walls and foundations. Rising damp shows salt stains and discolours walls from inside and out. We measure moisture at each layer of the external wall from bottom to top to determine groundwater height, then inspect foundation cracks and splits to pinpoint exact entry points.
Naeem is an older residential district in Jahra governorate near Naeem industrial zone where wells and shallow groundwater are common.
We measure moisture at multiple depths in the external wall because groundwater is the main cause of rising damp here in winter.
Sensitive sensor picks up leak noise through tiles and plaster
Flexible camera checks for cracks and corrosion inside supply lines
Tracing the hidden pipe route to narrow the search zone
Systematic check of suspect surfaces without lifting a single tile
Confirming whether moisture source is the tank or a supply pipe
Exact leak point confirmed before the repair team is engaged
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
After precisely measuring groundwater level we determine where to inject the barrier slightly below the damp zone. Effective injection requires accurate moisture location first, so we do not waste barrier on dry areas.
No, each crack needs separate injection based on its depth and angle. We identify all splits first with the moisture meter, then inject each one separately to stop water entry.