Circulation loop check
Finds blockages or leaks stopping hot water reaching distant bathrooms.

Farwaniya
Central heater repair in Hassawi usually starts with cold water reaching the second or third bathroom while the first stays warm. We climb to the roof to inspect the tank, pump and insulated pipes, then trace the distribution line until we find a break, leak or blocked valve.
Hassawi houses are mostly two storeys, with the roof tank on top and the electric pump beside it. The typical problem here is that pipes run the length of the roof then drop down the outside wall to each bathroom, and in intense summer heat the direct sun degrades the foam insulation and cools the water. We cut damaged sections, install thicker insulation and test pump pressure before restarting.
Hassawi is in Farwaniya governorate, where roofs and external pipes face direct sun and heat throughout the year.
We test hot water flow from each tap with a thermometer because pressure alone does not show temperature.
Finds blockages or leaks stopping hot water reaching distant bathrooms.
Checks body, connections and internal lining for corrosion or leaks.
Tests, services or replaces the pump if it has stopped circulating.
Inspects isolation and expansion valves; repairs any that leak or stick.
Repairs corroded or leaking copper runs connected to the heater unit.
Verifies the full circuit is sound after every repair before handover.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Long exposed pipes on the roof lose heat in transit, especially if the insulation has failed. We remove the damaged section and install fresh insulation at least 25 mm thick depending on the distribution line length.
If the valve is in the distribution line, no, we close an isolation valve first. But if the valve sits at the tank base, we must drain some water and use a special wrench to remove it without losing all pressure.