Pre-fit camera check
Line condition and diameter confirmed before valve position is chosen

Jahra
Backflow valve installation in Qasr starts by lifting the existing inspection chamber cover and running a camera through the main pipe. We select the appropriate valve size and install it at the primary discharge point. The pit is backfilled in layers of sand and gravel, and the valve closure is tested under high pressure.
Qasr homes have old main pipes running under narrow streets, with inspection chambers in house yards. The valve is installed inside the existing chamber or in a new shallow pit beside it if the old chamber is too small. We inspect the inlet and outlet pipes and check for salt deposits or cracks before securing the valve.
Qasr is in Jahra governorate, an older residential district where main pipework requires special attention.
Cold water testing precedes hot water testing because metal expansion affects valve sealing performance.
Line condition and diameter confirmed before valve position is chosen
Closest viable point to the public sewer for maximum protection
Valve set into the line without unnecessary tile breaking
Flap mechanism tested in both directions before the line is reconnected
Line filmed again to confirm valve seating and unobstructed flow channel
Correct siting verified relative to cesspit or inspection chamber position
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, if the chamber is deep enough and wide enough to accommodate the valve body. We inspect it with a camera first and measure the inlet and outlet connections. If space is tight, we dig a new pit right beside it.
Clogged valves lose sealing ability. We inspect yearly with a camera from the inspection chamber if blockages happen often in the area. If clogging occurs, the valve is removed, drained, cleaned or replaced.