Pre-fit camera check
Line condition and diameter confirmed before valve position is chosen

Farwaniya
Installing a backflow valve in Rehab starts by lifting the pit cover and running a camera into the main sewage line. We search for pipe falls, blockages and sediment causing backflow. The whole line is cleaned before the valve is set at the main entry point. Flow is tested both toward the pit and away to confirm the valve works.
Most Rehab houses sit on shallow foundations with pits close to street level, meaning sewage backs up to ground floors when street level rises. We check first whether the main line has proper fall from house to pit, because flat pipes trap sediment. If we find gravel or fat buildup we run a high-pressure clean before fitting the valve, otherwise the valve clogs fast.
Rehab is an older residential area in Farwaniya governorate, where most houses have individual pits and short sewage lines running below ground.
The valve is tested under full flow from all fixtures because an untested valve may fail when real backflow pressure hits.
Line condition and diameter confirmed before valve position is chosen
Closest viable point to the public sewer for maximum protection
Valve set into the line without unnecessary tile breaking
Flap mechanism tested in both directions before the line is reconnected
Line filmed again to confirm valve seating and unobstructed flow channel
Correct siting verified relative to cesspit or inspection chamber position
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Cleaning removes sediment and grease already inside, but does not stop street water flowing back into your house when levels rise. A valve lets water out only and closes automatically if backflow tries to happen.
We choose the valve size by the main pipe diameter leaving your house, not by pit size. If your pipe is 110mm we fit a 110 valve, if it is 160mm we fit a 160 valve.