Hot and cold supply
PPR runs sized for sink, dishwasher and fridge-water connections

Ahmadi
Kitchen first-fix in Mahboula starts with running lines from the roof tank or central source through ducts and walls. Mahboula has old and new villas, so we test current pressure and design lines for daily use. We secure pipes firmly and test waste before cabinet and floor installation.
Villas near Beach Road in Mahboula sometimes face low water pressure in summer due to general demand. We run a dedicated line from the roof tank if available, or install a pressure regulator to ensure steady kitchen flow. Waste passes through a floor trap under the kitchen then to the main stack with correct fall.
Mahboula sits in Ahmadi governorate on Beach Road, a mixed area of older villas and newer buildings.
We record water pressure at entry point before starting pipes and again after completion, because any large drop signals loss in the lines or joints.
PPR runs sized for sink, dishwasher and fridge-water connections
uPVC drain at correct fall to stop grease settling inside the pipe
Grease trap position and vent stack stub to block sewer odour entry
Gas supply stub-out to cooker position run before wall cladding closes
Supply and drain stub prepared at the right height for the water heater
Recorded pressure test on all supply lines before any wall is closed
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
A regulator stabilises available flow, but does not increase actual pressure. If total pressure is very low, the better solution is a higher roof tank or an additional storage tank that provides steady pressure.
We install a floor trap with a cleaning access at the bend, and use pipes of adequate diameter for quick flow. We advise the family not to pour oil and grease directly down the drain, and to clean the trap every month or two.