PEX pipe runs
Flexible concealed runs with the fewest cuts into finished walls

Ahmadi
PEX runs in Hadiya distribute water from the rooftop tank or central meter to every floor and room as needed. We run tubes at different diameters for the required pressure and flow, clipping them to inner walls with plastic clips. Each branch ends in a crimped brass head. The full network is tested at 9 bar pressure.
Hadiya has medium-size family homes and small apartment blocks, many with rooftop tanks for water storage. We start from the tank fill point and run main PEX branches to each floor, then split each branch to kitchen and bathrooms. Tank pressure is lower than the central network so we use slightly larger diameter tubes for sufficient flow.
Hadiya is a residential neighbourhood in Ahmadi governorate, located near Ahmadi City and home to local commercial and government services.
New PEX lines are flushed with sterile water before connecting to the tank to clear any factory particles.
Flexible concealed runs with the fewest cuts into finished walls
Brass press fittings that need no flame or solvent cement
Run before walls close to confirm every joint is sound
One valve per circuit so any line can be shut independently
Set to prevent sludge build-up and recurring blockages
Tying the PEX network to every use point across the building
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
If the bathroom is close to the tank we use 16 mm PEX. If it is far or on a lower floor we increase to 20 mm to compensate for pressure drop.
No, PEX is flexible and bends around corners easily without special bends. We use corner fittings only where the angle is too sharp to avoid kinking.