PEX pipe runs
Flexible concealed runs with the fewest cuts into finished walls

Jahra
A flexible PEX network in Nasseem starts at the main inlet and branches to every floor and bathroom. We use half-inch pipe on main runs and quarter-inch on final branches. We hold full pressure for 30 minutes before closing any wall. Nasseem demands high precision because most houses have multiple tanks.
Nasseem has modern villas and mid-rise apartments, with water arriving via government lines before distribution to lower and upper floors. We run PEX from the water meter in the front courtyard to multiple roof tanks, then branch from each tank to its own units. In Nasseem water has moderate salinity, so we use stainless steel fittings to prevent joint leaks. We test flow in each unit separately before floor handover.
Nasseem is a modern residential district in Jahra where villas and apartment blocks mix, most fed by separate roof tanks.
We measure water pressure at every end point using a digital gauge before final network documentation.
Flexible concealed runs with the fewest cuts into finished walls
Brass press fittings that need no flame or solvent cement
Run before walls close to confirm every joint is sound
One valve per circuit so any line can be shut independently
Set to prevent sludge build-up and recurring blockages
Tying the PEX network to every use point across the building
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, if they sit at roughly the same height. We install a balance valve between the tanks to equalize pressure and prevent backflow from the higher tank.
We cut the pipe on both sides of the break and fit a brass compression coupling that pulls the sections together. We don't need to open the whole wall, just the small break point.