Washbasin and wall-hung basin
Countertop or wall-hung, with supply lines and a sealed waste trap.

Capital
Sink and toilet fixture installation in Nuzha requires checking existing waste lines and floor trap depths. We connect each basin with strong flexible piping, test fast drainage without airlock and confirm no spillback before finishing.
Nuzha apartments and villas near the park have multiple bathrooms, and waste must travel between different floors. We check the fall on each waste line from upper bathrooms down to the main vertical stack and confirm no lines cross or compress. If fall is inadequate, we raise the basin outlet or increase diameter from one and half to two centimetres.
Nuzha lies in Kuwait governorate near Nuzha Co-op and Al Nuzha Park, a multi-storey residential district.
We test drainage from each bathroom with high water volume at once to check for blockage or backflow.
Countertop or wall-hung, with supply lines and a sealed waste trap.
Wall or counter mount with correct waste outlet and supply valves.
Pan, cistern or in-wall frame, sealed base and flush line fitted correctly.
Tray, linear drain, riser and mixer connected and water-tested before tiling.
Set level, overflow solvent-welded, mixer and waste fully connected.
Supply, pump and jet lines connected with pressure test before finishing.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, if the waste line has adequate diameter and steady fall. We join both basins with a Y-shaped branch before the floor trap, leaving a small air vent hole open.
We run a horizontal pipe under the tiles with a proper angle toward the stack, checking each joint by eye and with a listening device. If the run exceeds three metres, we add a separate vent pipe reaching the roof.
