Concealed frame fitting
Steel carrier frame anchored at the specified height inside the wall

Farwaniya
A wall-hung toilet in Jleeb Al-Shuyoukh is installed quickly because dense residential areas need organized work. We anchor the frame solidly into the wall, run waste and supply from a suitable point, and pressure-test before leaving.
In Jleeb Al-Shuyoukh houses, apartments and shops stand closely packed, bathrooms are cramped with thin walls and waste lines shared between units. Wall-hung toilet placement means choosing a load-bearing wall that does not divide with a neighbour's unit. We probe wall thickness first and confirm concrete depth before drilling anchors. Waste drops through 110 mm pipe to a main stack serving more than one bathroom, so we test flow without blockage from other flats.
Jleeb Al-Shuyoukh is in Farwaniya governorate, a dense market area of multi-storey residential units.
We test the main waste line from your unit and from the floor above because water can back up from a blocked stack.
Steel carrier frame anchored at the specified height inside the wall
Waste pipe set at the correct fall to prevent backflow and odour
Supply line connected with an accessible isolation valve behind the service panel
Flush volume and fill valve pressure adjusted to stop continuous water loss
Bowl hung on frame studs with correct bolts and seat fitted firmly
Full leak check before wall is closed and again after cladding is in place
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes if the wall is load-bearing and at least 15 cm thick. We probe and choose long anchor bolts that reach sound concrete behind the block. If thinner we suggest additional metal bracing.
Noise usually comes from loose waste pipes or slack anchors. We inspect the pipes and brackets and tighten them firmly, and if waste vibrates we fit extra metal clips to the load-bearing wall.