Concealed frame fitting
Steel carrier frame anchored at the specified height inside the wall

Hawalli
Wall-hung toilet installation in Shaab requires checking bathroom walls because some buildings rest on foundations near the groundwater table. We set the frame deep enough, run supply and waste, adjust drainage and perform final pressure testing.
In Shaab's beachfront areas, humidity is higher and walls need extra sealing before fitting. The frame is set deeper into the wall and the concrete is dampened before securing with strong adhesive mortar. The waste line runs horizontally from the floor trap and is tested with pressurised water to prevent leaks and mould. We choose moisture-resistant materials for every connection under the tiles.
Shaab is in Hawalli governorate near beachfront parks, where coastal humidity affects internal building conditions.
The waste is tested under cold water pressure for fifteen minutes before cistern installation to verify the seal.
Steel carrier frame anchored at the specified height inside the wall
Waste pipe set at the correct fall to prevent backflow and odour
Supply line connected with an accessible isolation valve behind the service panel
Flush volume and fill valve pressure adjusted to stop continuous water loss
Bowl hung on frame studs with correct bolts and seat fitted firmly
Full leak check before wall is closed and again after cladding is in place
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, if the floor trap is near the water table, moisture can collect in the pipe. We fit a short run with adequate fall and flush it clean before final pressure test.
Yes, we seal every pore of the concrete against moisture before fixing. We use mould-resistant adhesive and wait for complete drying before installing the pan.
