Concealed frame fitting
Steel carrier frame anchored at the specified height inside the wall

Hawalli
A wall-hung toilet in South Surra requires checking the villa wall, old or new, before we mark the frame position. We run water and waste with proper fall, bolt the frame tight, fit the cistern, and pressure-test with care.
South Surra villas are either old with thick earthen walls or new with insulated concrete walls. Old walls need special fixings because the clay crumbles, while new walls take standard bolts easily. In both cases, we place the frame near the main soil pipe in the outer wall to avoid long runs beneath the floor.
South Surra is in Hawalli governorate, a villa area with both old and new builds and varied drainage setups.
Before fixing begins, we test wall strength with a small trial hole to confirm material type and proper bolt depth.
Steel carrier frame anchored at the specified height inside the wall
Waste pipe set at the correct fall to prevent backflow and odour
Supply line connected with an accessible isolation valve behind the service panel
Flush volume and fill valve pressure adjusted to stop continuous water loss
Bowl hung on frame studs with correct bolts and seat fitted firmly
Full leak check before wall is closed and again after cladding is in place
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
We examine it in detail first. If the frame joints are tight and the metal is not deeply rusted, we reuse it. But deep rust or visible cracks mean a new frame is needed.
We drill at least 12 to 15 centimetres deep and use expansion bolts that fill the hole completely. Each bolt is pull-tested before the frame is hung on it.