Position and height
correct mounting height marked before any fixing begins

Hawalli
A double vanity in the master bathroom is a frequent request for washbasin installation in Zahraa, where independent houses in Hawalli governorate often have room for two basins side by side. Two bowls draining into one wall outlet need their branch sized and angled with care.
Each basin in a double vanity gets its own trap, and the two waste arms meet in a branch before the wall outlet. If that branch is too small or too flat, the second basin gurgles or drains slowly whenever both run together during the morning rush. In Zahraa's houses the original outlet was usually placed for a single basin, so we either run a short manifold across the cabinet back or open a second outlet where the wall allows it.
Zahraa is a residential area in Hawalli governorate of independent family houses, many with a master bathroom on the upper floor.
Two basins sharing one waste outlet need a branch sized for both, or the second bowl gurgles when they drain together.
correct mounting height marked before any fixing begins
drain slope set and trap fitted with a proper water seal
hot and cold supply connected through new isolation valves
sanitary silicone applied at the basin edge to block water ingress
mixer seated and cartridge aligned to stop dripping at rest
water run and every joint checked before wall or cabinet is closed
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Usually the shared branch is undersized or too flat, so air is pulled through the trap, and we correct the branch rather than the basin.
Yes, each basin gets its own pair of angle valves, so one can be shut for maintenance while the other stays in use.