Position and height
correct mounting height marked before any fixing begins

placing the basin, setting the waste run, connecting supply lines, and testing every joint
correct mounting height marked before any fixing begins
drain slope set and trap fitted with a proper water seal
hot and cold supply connected through new isolation valves
sanitary silicone applied at the basin edge to block water ingress
mixer seated and cartridge aligned to stop dripping at rest
water run and every joint checked before wall or cabinet is closed
describe the basin type, location, and any issue with the existing outlet
technician checks waste and supply points and notes what needs adjustment
basin fixed, trap connected, supply lines fitted, edges sealed
water run and every joint inspected before any cabinet or wall is closed
work area cleaned and any maintenance notes passed on to you
absorb pipe movement and resist cracking under the basin connection point
resists mineral scale common in Kuwait water and holds the odour seal reliably
applied at the basin perimeter to prevent water tracking behind the basin body
used together on threaded fittings for a dual seal that will not crack under pressure
note whether the waste outlet is in the wall or floor as it determines the trap type needed
have the basin dimensions or model name ready so the technician can confirm fitting compatibility
check whether the mixer includes flexible tails or let us know so we bring the right fittings
know where the nearest water isolation valve is so supply can be cut quickly at the start








Part of Sanitary fixture installation · All services · Back to the home page
no fixed price list applies; these factors together determine the actual quote
wall-hung basins need deeper wall anchoring than countertop units
a corroded or misaligned outlet needs adjustment before the basin can be set
relocating drain or supply runs requires breaking and reinstatement work
missing flexible tails or new valves add to the overall materials cost
upper floors or confined cabinet spaces increase working time on site
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else’s home is not ours to be careless in.
Do not take our word for it. Look at the work yourself.
The leak is marked before a single tile comes up.
A leak does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Six governorates, 139 areas.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Usually yes, if the new basin dimensions match the existing waste and supply positions. Small differences in mixer hole spacing or waste outlet height may need a minor adjustment but rarely require wide breaking.
The most common cause is the trap seal drying out from infrequent use. Running the tap usually restores it. If the smell persists, the rubber seal inside the trap has likely deteriorated and needs replacing.
You can supply the basin yourself or arrange for us to source it. Either way, the fixture should be on site before the appointment to avoid delays on the day.
Old galvanised iron corrodes internally, narrowing the bore and reducing pressure at the tap. We recommend replacing the exposed section with PPR or uPVC during the installation to restore proper flow.
Not always. The basin needs a deck hole sized for the mixer base, and pull-out hoses need enough clearance below the basin. This should be confirmed before purchasing the mixer to avoid a mismatch.