Pipe repair
PPR, uPVC and corroded galvanised iron joints and runs

Farwaniya
Plumbing repair in Ardhiya Industrial handles intricate networks of underground and rooftop water and waste lines. We check joints, valves and pump faults before water cuts off an entire production line.
Warehouses and factories in Ardhiya rely on rooftop pump sets that lift water from massive ground tanks to distribution points. A fault in the pump valve or a leak in an overhead joint stops work at once, so we start by checking the pump head, filters and steel lines. We test water pressure at each supply point and trace any leak from the main to the branch until we isolate the fault.
Ardhiya Industrial sits in Farwaniya governorate, an area of massive warehouses and workshops where each factory has its own pump system.
We remove the faulty valve and test it under full water flow before reinstalling it to ensure the pump recovers full pressure.
PPR, uPVC and corroded galvanised iron joints and runs
repair or replacement of leaking or stiff mixers and isolation valves
tracing low pressure to scale buildup, a blocked aerator or a pump fault
fitting toilets, cisterns, basins and floor drains correctly and leak-free
pressure test on the line after every repair before closing the wall
locating the exact fault before any decision to break or repair
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
We measure water pressure right after the pump and before the valve. If pressure is low there, the pump head is faulty; if it drops past the valve, the valve is the culprit.
We uncouple the joint and inspect the inner seal ring and thread. If they are not worn, a new gasket stops the leak; otherwise we replace the entire coupling with a matching diameter one.