Crack mapping by camera
Internal camera maps every crack and its depth before work begins

Farwaniya
Fibreglass tank repair in Dajeej addresses tanks exposed to strong winds, desert dust and extreme heat. We inspect for cracks and splits caused by thermal stress, seal with durable resin, then test with a full fill to ensure the repair holds.
In Dajeej, tanks on house and building roofs face harsh natural elements, with temperatures soaring in summer and winds battering the structure. This puts relentless stress on the resin, causing hairline cracks that widen over time. We climb to the roof and run our hands over the outer tank walls under light, hunting for any warp or irregular lines. Desert cracks may run deep, so we use thick, non-toxic resin.
Dajeej is a desert-fringe district in Farwaniya governorate where tanks face extremely harsh climate conditions.
Before handover we test every repair by filling the tank then leaving it in direct sun for two hours to confirm the resin withstands heat.
Internal camera maps every crack and its depth before work begins
Grinding the area around the crack ensures the resin bonds properly
Resin-saturated glass-mat layers fill the crack and restore structural stiffness
Delaminated sections are removed and rebuilt with matching laminate material
Full interior coat with epoxy rated safe for potable water contact
Camera confirms no remaining cracks or coating bubbles before the tank refills
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, but the resin must be flexible, not brittle, to tolerate minor tank movement. We choose resin formulated to withstand desert conditions.
Yes, dust sticks to wet resin and weakens it. We cover the tank with protective cloth after repair and leave it for several hours before removing the covering.