Isolation valves
Repair or replace main and branch isolation valves that no longer shut fully.

Jahra
Valve repair in Sulaibiya Industrial covers valves on thick-walled water pipes under high working pressure. The valve stops closing completely when internal parts are damaged by constant vibration and pressure. We open the industrial valve, inspect disc, springs and seat, replace damaged parts and test by pumping water at full system pressure.
Sulaibiya Industrial has treatment plants and water distribution lines of very large diameter under very high pressure. Valves here withstand high surge forces, and when fluid moves fast through pipes, vibration transfers to the valve body. Internal springs lose tension and the disc moves loosely instead of seating firmly on the seat. We disassemble the valve, measure disc and spring thickness, and replace necessary parts with matching industrial specifications.
Sulaibiya Industrial sits in Jahra governorate where water treatment and distribution plants concentrate, so valves face higher pressure and heat than residential areas.
After reassembly, the valve is tested under actual system pressure to ensure full closure with no seep under heavy load.
Repair or replace main and branch isolation valves that no longer shut fully.
Fix stiff or leaking ball valves caused by scale deposits around the ball seat.
Repair broken or corroded gate valve stems common in older Kuwaiti homes.
Adjust or replace pressure-reducing valves causing fluctuating supply pressure.
Repair float valves in ground and roof tanks that overflow or fail to shut off.
Replace failed check valves that allow backflow in pump and tank feed lines.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, but the valve must be isolated from the main line first before opening. We close the isolation valve upstream of the work point and relieve line pressure by opening the lower drain valve before any disassembly.
If the disc or seat is deeply scored or metals are corroded, repair will not hold. We inspect internal parts first, and if we see deep wear we recommend a new valve meeting the same industrial specifications.