Acoustic surface scan
Tracing the leak sound through tile and screed layers

Hawalli
Leak detection under tiles in Bidaa focuses on pipes near seafront exposures and external walls facing continuous humidity. We scan damp areas and test external pipes with special attention before any breaking decision.
The Bidaa area near Salmiya seafront experiences very high humidity and constant salt exposure, so external pipes corrode much faster than inland. Most houses have modern bathrooms and fittings but old pipes under floors remain weak. We start with visual inspection for black staining and distortion in external tiles, then insert a flexible borescope camera into drain openings to see pipes inside walls without breaking.
Bidaa is a residential area in Hawalli very close to Salmiya seafront, where marine humidity directly affects pipe and metal quality.
We measure pipe wall thickness with ultrasound to gauge corrosion before recommending replacement or repair.
Tracing the leak sound through tile and screed layers
Isolating the suspect line and measuring pressure drop to confirm fault location
Filming inside the pipe from the nearest access point to view the crack
Marking the exact spot on the tile surface to minimise breaking area
Checking pipe branches hidden inside the adjacent ceiling or wall
Handing the confirmed location directly to the repair team
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Much more so, because salt and humidity accelerate internal metal corrosion. Internal pipes are protected from direct exposure but external ones may fail within five years of installation.
If corrosion is only surface-level it can be cleaned and recoated with protective paint. If corrosion is deep and creates small holes, at least the damaged section must be replaced.