Acoustic surface scan
Tracing the leak sound through tile and screed layers

Capital
Leak detection under Doha tiles focuses on homes near the coast where moisture and salt speed up copper pipe corrosion. We scan floors with a thermal probe to see the temperature difference between dry and wet zones, then pinpoint the exact pipe line. The result guides you to the least expensive repair without breaking tiles.
Doha homes near the port and marina face constant moisture in concrete, making aged pipes prone to slow leaks. Walls and floors absorb salt from the air, and water seeps from copper and plastic joints. We use a thermal detector that reads the temperature difference between cold pipes and the damp surroundings, letting us map the pipe line precisely under tile.
Doha sits near Kuwait Port and the Marina in the capital, an area where coastal moisture affects infrastructure heavily.
We measure salt deposit thickness on exposed pipes to forecast the extent of possible leaking in hidden zones.
Tracing the leak sound through tile and screed layers
Isolating the suspect line and measuring pressure drop to confirm fault location
Filming inside the pipe from the nearest access point to view the crack
Marking the exact spot on the tile surface to minimise breaking area
Checking pipe branches hidden inside the adjacent ceiling or wall
Handing the confirmed location directly to the repair team
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, salt causes electrochemical corrosion in copper that creates tiny holes. In Doha near the port, we expect copper pipes older than ten years may be leaking inside the concrete.
We trace bent and straight pipes alike, because the thermal detector reads temperature difference, not pipe shape. We map every bend and direction change on a survey sheet before any work.