Roof-tank pump
Transfers water from ground tank to roof tank reliably.

Ahmadi
Water pump installation and service in Mahboula towers often comes down to the suction side. Along Beach Road, transfer pumps sometimes sit above the ground tank on a long suction pipe, where air leaks and cavitation wear them out, so we rework the suction before anything else.
In the high-rise blocks near Mahboula Co-op and Beach Road block 12, a pump that lifts water up into itself before pushing it to the roof loses prime whenever a foot valve leaks or a joint draws air. It rattles, delivers less and eats its impeller. Where the plant room allows, we lower the pumps to sit beside the tank with a flooded suction, shorten and enlarge the suction line, and fit an eccentric reducer so no air pocket forms.
Mahboula is an Ahmadi seafront district of high-rise towers along Beach Road, each lifting water from large ground tanks.
Where space allows, transfer pumps are set level with the tank bottom so they always start flooded.
Transfers water from ground tank to roof tank reliably.
Keeps hot water at the tap without a long wait.
Sets correct cut-in and cut-out points, stops short-cycling.
Evacuates cesspits efficiently with a non-return valve fitted.
Lifts sewage from low-level units to the drainage network.
Protects basements from water accumulation via float-activated switch.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
That sound is usually cavitation, when the pump cannot draw water easily and vapour bubbles collapse inside it. Fixing the suction side stops it and protects the impeller.
A leaking foot valve or a small air leak on the suction joints lets the water column drop back. Flooded suction removes the need for priming altogether.