Live pressure reading
Measuring cut-in and cut-out values before touching anything

Ahmadi
When water suddenly stops in Mangaf, the automatic pressure switch usually no longer triggers the pump to start. We go to the roof, read the pressure gauge, open the tank and inspect the coil and springs, then reset the cut-in point.
Old Mangaf houses often have rooftop tanks mounted straight on concrete beams on exposed flat roofs under intense sun. The automatic switches in these tanks suffer from heat, and the coil separates or springs weaken. We check the air cushions first because losing them means losing pressure, then decide whether to adjust settings or replace the switch.
Mangaf sits beside Abu Halifa in Ahmadi governorate, a district of heritage houses where manual pressure systems were later converted to automatic.
In high heat we test the switch through a full cycle, let it cool, then run it again to confirm settings remain stable.
Measuring cut-in and cut-out values before touching anything
Testing the air bladder charge and refilling it if pressure is lost
Cleaning contacts or fitting a new switch matched to pump capacity
Calibrating both thresholds precisely to prevent rapid on-off cycling
Inspecting wiring and terminal resistance at both switch contacts
Running the pump and confirming stable pressure through a full cycle
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, intense heat weakens the metals and springs over time. We recommend shading the tank or placing insulation around the switch to reduce direct sun exposure.
If the springs and coil are intact we adjust the settings only. If the coil is separated or springs are broken, replacement is required.