Live pressure reading
Measuring cut-in and cut-out values before touching anything

Hawalli
Some Zahraa homes have swapped the old pressure switch for an electronic flow controller, so pump pressure switch repair there now includes these units. When the pump starts for a glass of water or fails to start at all, the controller's check valve or sensor is usually the cause.
Electronic controllers start the pump on a pressure drop and keep it running while water flows, with a built-in check valve and dry-run protection. Scale on the flow paddle or a sticking check valve upsets that logic. In Zahraa we clean or replace the controller's internals, check its start pressure against the height of the highest outlet, and confirm the dry-run cut-off still works with the tank low.
Zahraa is a Hawalli residential area of family houses, most with their own pump, tank and controller.
A controller whose start pressure is set too low leaves the highest taps slow to respond.
Measuring cut-in and cut-out values before touching anything
Testing the air bladder charge and refilling it if pressure is lost
Cleaning contacts or fitting a new switch matched to pump capacity
Calibrating both thresholds precisely to prevent rapid on-off cycling
Inspecting wiring and terminal resistance at both switch contacts
Running the pump and confirming stable pressure through a full cycle
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Only if the controller keeps failing. A switch with a properly charged vessel is simple and reliable, while a controller saves space. We explain both and fit what suits your pump room.
Usually the dry-run protection has tripped because it sensed no flow. Either the tank is low or the suction has air in it, and we check both before resetting.