Tank and line check
Tank size and pipe run checked before any pump is chosen

Ahmadi
Roof tank pumping in Dhaher needs a strong pump to handle the height pressure and long distances between wells and buildings. We check the tank and pipework, fit the pump and run full pressure tests before release.
Most Dhaher buildings near the Saudi border use deep wells and heat-insulated roof tanks. The pump here pushes water uphill across long distances under sand, so we ensure the pipe has no leaks and tank connections are tight. We test pressure during peak summer load because cool months can hide faults that only show under stress.
Dhaher sits in Ahmadi governorate near the Saudi border, where wells are deep and roof tanks are vital for stable supply.
Pump connections are tested at pressure one third higher than normal load to ensure the motor can handle sudden surges.
Tank size and pipe run checked before any pump is chosen
Type and capacity matched to actual tank height and demand
Pump seated on isolation pads to stop vibration reaching the structure
Inlet and discharge lines fitted with non-return and isolation valves
Outlet pressure measured and confirmed stable under normal fixture load
All joints inspected for leaks before the job is signed off
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Extreme heat above the tank raises water and motor temperature together, cutting motor efficiency. We select heat-rated pump motors and ensure tanks are shaded or painted with reflective coating.
Yes, if they sit at the same height and close to each other. We fit non-return valves on each supply line to stop water flowing from the higher tank to the lower one.