Tank installation
Mounting the tank on a level concrete base to protect its base from cracking

Hawalli
In the towers along Gulf Road, a roof tank installation in Salmiya has to serve floors that sit only a few metres below it. Gravity alone gives the top floors almost no pressure, so we pair the tank with a small booster set dedicated to the upper levels.
A Salmiya tower tank feeds most flats well by gravity, but the last two or three floors below the roof get a weak trickle, and showers with thermostatic mixers may refuse to run. A booster set drawing from the same tank and feeding only those upper floors fixes this without over-pressurising the rest of the building. We fit it with its own pressure vessel, dry-run protection tied to the tank level, and a separate riser, leaving the gravity supply to the lower floors untouched.
Salmiya, along Gulf Road near Marina Mall and Sultan Centre, is dense with residential towers fed from roof tanks.
Thermostatic shower mixers often need more pressure than a tank one floor above can supply by gravity.
Mounting the tank on a level concrete base to protect its base from cracking
Running the fill line and distribution line to floors in PPR pipe
Installing the overflow at correct slope so no water pools on the roof
Connecting the existing transfer or pressure pump and setting its switch
Fitting a brass float valve sized to the tank for accurate fill cut-off
Testing all joints under pressure before handover to confirm no leaks
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
The roof tank sits only a few metres above you, which gives very little gravity pressure. A booster set for the upper floors is the usual fix.
No. It feeds a separate riser to the upper floors only, while the lower floors stay on their existing gravity supply.