Burner inspection
Clean and adjust the burner for even, complete ignition every cycle

Ahmadi
Gas heater service in Julaiaa handles high water pressure from rooftop tanks, requiring inspection of check valve, safety group and electrical grounding. We test pressure, ignition and drainage, give you a detailed report before restarting.
Julaiaa homes sit in a southern desert area with very tall rooftop tanks, and the excess pressure from such heights puts heavy load on all heater parts. The check valve stops hot water flowing back into the cold line, the safety group releases excess pressure, both need yearly inspection. If either fails the heater can burst from pressure or send hot water into the cold line.
Julaiaa lies in southern Ahmadi governorate, a residential area that depends on very tall water tanks.
We test the safety drain hole by manually opening the relief valve for one second and watch water flow because any blockage disables the safety system.
Clean and adjust the burner for even, complete ignition every cycle
Test every joint with detection solution to locate any minor leak
Inspect the flue path and confirm combustion gases exit the space
Measure thermostat accuracy and test the thermal cut-off safety valve
Check the tank body and the sacrificial anode for corrosion progress
Measure incoming water pressure and confirm it suits the unit's rating
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
The check valve allows water flow in one direction only from cold to hot. The safety group contains a valve that opens automatically when pressure exceeds safe limit and releases excess water outside.
Yes, lime scale reduces water flow through the exchanger and hot water may arrive lukewarm from weak heating. Annual cleaning preserves both flow and temperature.