Burner inspection
Clean and adjust the burner for even, complete ignition every cycle

Ahmadi
Gas heater service in Mahboula towers has to deal with the wind. On high balconies along Beach Road, gusts off the Gulf can push straight back down a heater's flue, so we check the terminal and fit a proper wind guard that keeps exhaust leaving and the flame steady.
Flats high in the towers near Mahboula Co-op and Beach Road block 12 catch far stronger wind than villas at street level. A short flue with a plain open end lets gusts drive exhaust back into the heater, which trips its safety device or, worse, spills fumes onto the balcony. We check the flue for the length and terminal the maker specifies, fit a wind resistant cap, confirm the heater restarts cleanly in gusty conditions, and test for spillage at the draught diverter.
Mahboula is an Ahmadi seafront district of high-rise towers along Beach Road, whose upper balconies face strong Gulf winds.
Flue length and terminal are checked against the maker's instructions, then spillage is tested at the draught diverter.
Clean and adjust the burner for even, complete ignition every cycle
Test every joint with detection solution to locate any minor leak
Inspect the flue path and confirm combustion gases exit the space
Measure thermostat accuracy and test the thermal cut-off safety valve
Check the tank body and the sacrificial anode for corrosion progress
Measure incoming water pressure and confirm it suits the unit's rating
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Almost certainly. Wind forcing exhaust back down the flue trips the safety device. A correct terminal and wind cap usually stops it.
A room sealed, fan assisted model copes with wind far better than an open flue heater, and is worth considering when the current one needs replacing.