Burner inspection
Clean and adjust the burner for even, complete ignition every cycle

Farwaniya
Gas heater inspection in Rabiya includes testing the burner, thermostat, safety valve and flue. We verify full safety, measure performance and test the flame on live gas before handover.
Old Rabiya residential houses have gas heaters of various types and ages. Some are mounted on exterior walls, others inside kitchens or bathrooms. Aged pipes may rust inside or clog with mineral deposits. We inspect every pipe from gas source to burner for rust, blockages and leaks. We test gas pressure at the burner to ensure it is enough for a strong, steady flame.
Rabiya sits in Farwaniya governorate, a traditional residential neighbourhood with family houses established for decades.
We check every joint with soapy solution to spot any leak before running full gas again.
Clean and adjust the burner for even, complete ignition every cycle
Test every joint with detection solution to locate any minor leak
Inspect the flue path and confirm combustion gases exit the space
Measure thermostat accuracy and test the thermal cut-off safety valve
Check the tank body and the sacrificial anode for corrosion progress
Measure incoming water pressure and confirm it suits the unit's rating
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Iron oxide forms from moisture and oxygen trapped between pipe walls. This rust flakes and blocks the opening or enters the burner to jam sensors. We remove heavily rusted pipes and replace them with copper or galvanized steel.
We extinguish the flame manually or block air to the burner until it dies, then watch the valve shut gas immediately before any leaks. We repeat the test three times to confirm consistent response.