Element condition check
Resistance measured to confirm whether element is scaled, shorted or open

Hawalli
Inspecting and replacing the heating element and thermostat in Bidaa heaters starts from knowing that most tanks here cycle intermittently due to heavy loads in modern apartment blocks. We open the tank and check element condition and lime buildup. We remove damaged parts, fit an element with appropriate power and a precise thermostat and test performance under full pressure.
Bidaa is a relatively modern residential area with tall apartment blocks and mid-range flats near the Salmiya seafront. Hot water tanks here are large to cover whole-building demand and usually sit in a plant room or on a common roof. Water in this area is relatively hard, causing lime deposits to build up quickly on the element surfaces, reducing heat transfer efficiency. Before replacement we check deposit thickness and decide whether cleaning is enough or full element replacement is needed.
Bidaa sits in Hawalli governorate near the Salmiya seafront, where salt air affects water quality.
We measure lime layer thickness on the element before replacement because hard water here deposits faster than other areas.
Resistance measured to confirm whether element is scaled, shorted or open
Cutout points tested and temperature calibration verified before fitting new part
Scale deposits inside the tank assessed as they reduce heating efficiency
Anode protects the tank from corrosion and is inspected at every service visit
Wiring and terminals inspected for safety before the new element is energised
Heater run and water temperature confirmed at the tap before the visit ends
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Cleaning improves heat transfer for a time, but if deposits are more than a millimetre thick on the surface, the element loses efficiency quickly. In this case replacement is better than repeated cleaning.
We do not recommend filtering cold water before the tank as it reduces pressure. But if water is very hard, we suggest adding a small filter on the hot supply pipes only after the tank to reduce new deposits.
