Collector panel check
Absorber tubes, flow channels and surface condition inspected for faults

Hawalli
Solar heater repair in the Ministries Area usually starts with checking panels on the roof and inspecting copper pipes and valves. We test system pressure and water temperature, identify why output has dropped, then repair or replace the faulty part.
Ministry buildings often share roof space across multiple units, and solar panels face desert dust and hot winds year-round. We clean panels of grit and inspect the upper tank cover for leaks, and if water is not heating we check the mixing valve and thermostat. Old pipes may need extra insulation in summer to cut heat loss to the surroundings.
The Ministries Area sits in Hawalli governorate near the Kuwait Government Ministries Complex, mixing office buildings and staff residential quarters.
Every supply pipe is tested under 3 bar pressure before handover to confirm there are no leaks.
Absorber tubes, flow channels and surface condition inspected for faults
Tank body, thermal insulation layer and sacrificial anode condition assessed
Circulation pump, valves and connecting pipework between panel and tank
Thermostat calibration, expansion vessel pressure and safety valve checked
Acoustic and visual tracing of panel and pipe leaks before any breaking
Pressure and temperature test confirms full output is restored before leaving
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
The mixing valve might be stuck mixing cold water with hot, or the thermostat set too low. We disassemble the valve, clean scale deposits and reset the thermostat to the correct temperature.
Small cracks or minor leaks can be patched in the glass and sealing, but if the inner heat collector is broken, replacement is faster and cheaper than hunting internal cracks.