Site level survey
Ground elevation readings confirm the natural direction water will travel

Farwaniya
Storm-drain design in Rai Industrial is completely different from residential: massive buildings, vast roofs and paved concrete areas. We calculate flow for the worst-case storm and design huge pipes with multiple detention tanks. Drawings cover every square metre of land.
Warehouses and factories in Rai Industrial have large roofs and expansive paved yards, mostly asphalt. When rain falls, huge water volumes flow within minutes and the municipal sewer alone cannot handle it. We design large underground storage tanks that hold water temporarily then release it gradually after rain stops. We position tanks to avoid conflict with existing foundations and utilities.
Rai Industrial sits adjacent to The Avenues Mall in Farwaniya governorate, where large warehouses and factories cluster together.
Tank volume is calculated from roof and paved area, plus one-hour worst-case rainfall intensity for the zone.
Ground elevation readings confirm the natural direction water will travel
Expected flow volume determines the correct pipe diameter for each run
Gullies are positioned so no low point is left without an outlet
Chambers placed at every direction change to allow future maintenance
Adequate slope prevents sand settlement and keeps flow gravity-driven
Final discharge point set away from foundations, fencing and neighbouring plots
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
We measure roof and yard area and multiply by Farwaniya's one-hour rainfall coefficient, approximately 40 mm. The result is water volume that will reach the tank in worst case, and the tank must hold all of it.
Yes, so we position it at least 1.25 metres from existing footings. We design the tank with reinforced walls and base slab and recommend soil testing before construction to determine foundation thickness needed.