Pipe routing
Mapping every copper run before walls are plastered over

Jahra
Central gas in Salmi, a border area, demands robust installation and strict testing because pipes may endure vibration from border traffic movement. We build the network from the entry meter to every hob and heater with complete pipe protection. Every joint is tested under high pressure and documented.
Salmi houses near the Kuwait-Iraq border are scattered, needing long gas runs from a central supply point. Vibration from heavy trucks and daily traffic causes extra wear on joints. We use heavy metal clips and watch for pipe movement during testing. Soldered joints are tightened fully then checked with concentrated soapy solution.
Salmi is a border zone in Jahra governorate near Bourdah border crossing, which separates Kuwait and Iraq.
Gas pipes in Salmi are inspected after six months to detect any clip loosening from continuous traffic vibration.
Mapping every copper run before walls are plastered over
Branching the network to each appliance position per plan
Fitting an isolation valve at every outlet for future servicing
Dry nitrogen charge and pressure hold test before handover
Core drilling wall openings and securing pipes with correct clips
Recording final pipe routes for future maintenance reference
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, repeated vibration can cause fatigue cracking in soldered joints. We use heavy metal clips at close intervals between supports, and long exposed runs are anchored with flexible rings that absorb vibration.
We run a handheld gas detector over the house monthly for early detection. If we find a small leak, we remove the damaged section, solder new couplings and test under high pressure before reactivating.