Gas leak detection in Hateen often has to follow a long vertical run. Many villas here keep cylinders at ground level while a second kitchen sits in the roof annex, so the pipe climbs two floors through walls and slabs, and every joint and sleeve along that route is a possible leak point.
A gas riser in a Hateen villa passes through the ground and first floor slabs inside sleeves, and where a sleeve was never sealed, the pipe can rub against concrete as the building moves with the heat. We isolate the riser from the cylinder end, pressurise it and watch a gauge for pressure decay, then work up floor by floor with a sniffer at each joint, sleeve and bracket. If a section is inside a closed wall, the reading tells us where to open the smallest possible access.
Hateen is a Hawalli governorate area of two-storey villas where many roof annexes include a second kitchen on the gas line.
A gas pipe passing through an unsealed slab sleeve can wear against concrete as the building expands and contracts.
sensors detect escaping gas through walls without any breaking
network segments isolated and pressure drop measured to find the faulty section
every joint and valve checked with leak-detection fluid where leakage is suspected
gas isolated to the faulty section immediately to keep the building safe
only the damaged section repaired or replaced, rest of network left intact
full pressure test after repair confirms the entire network is tight
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
The riser to the roof kitchen often runs beside the stair core, so a leak at a joint or sleeve along it shows up there first.
Rarely more than a small opening. The pressure test and sniffer readings narrow the leak to one section before anything is opened.