Electronic detection
sensors detect escaping gas through walls without any breaking

Capital
Gas leak detection in Shuwaikh Industrial focuses on main gas lines for warehouses, storage and logistics facilities. We inspect heavy connections and large pipes from the supply source to heating units and industrial equipment. We use high-pressure standards to verify all connections before restart.
Shuwaikh Industrial facilities near factories and quarries house heavy gas lines with boilers and large industrial burners. These steel pipes stretch hundreds of metres across floors and steel columns and face moisture and equipment vibration. We start from the external tank and trace the entire line to furnace and boiler outlets, focusing on threaded joints and heavy flanges bearing constant pressure.
Shuwaikh Industrial sits in Kuwait governorate and is zoned for factories, logistics and distribution services.
We test high-pressure lines at 3 bar because industrial boilers require steady pressure throughout the day.
sensors detect escaping gas through walls without any breaking
network segments isolated and pressure drop measured to find the faulty section
every joint and valve checked with leak-detection fluid where leakage is suspected
gas isolated to the faulty section immediately to keep the building safe
only the damaged section repaired or replaced, rest of network left intact
full pressure test after repair confirms the entire network is tight
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, heat and vibration can weaken welds over time. We inspect each flange with magnification and sensitive detection, and recommend rewelding or replacement if weakness appears.
Yes, we ask for furnaces and boilers to be halted during the full check and pressure test. After handover, equipment is restarted gradually while monitoring pressure.