Copper or steel pipe run
Correct diameter pipe sized to kitchen appliance load and inlet pressure.

Farwaniya
A kitchen gas line in Abbasiya must run from the external inlet to the oven and hob without leaks. We inspect every joint with a detector, test under live pressure, and record results on the test sheet.
Abbasiya has many small flats in older buildings with tight kitchens and moisture creep from adjacent bathrooms. A gas line here needs extra protection against corrosion from damp. We use copper pipe wrapped in plastic sheath and fix it away from walls to allow air circulation.
Abbasiya is in Farwaniya governorate, a dense residential quarter of apartment blocks and intersecting narrow streets.
The line is tested at minimum 100 millibars for 10 minutes with no pressure drop before job sign-off.
Correct diameter pipe sized to kitchen appliance load and inlet pressure.
Individual outlet with isolation valve for each hob, oven or fryer.
Pipe run inside protective conduit or channel with ventilation clearance observed.
Joints finished by brazing or press-fit method suited to the pipe material.
Nitrogen pumped to test pressure and held to confirm every joint is tight.
Inspection of an existing run and repair of any corroded section or weeping joint.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Moisture accelerates bare copper corrosion, but a properly sheathed line stays protected. We test periodically and advise wiping condensation from the sleeve if heavy moisture builds up. Plastic sheath blocks direct contact between metal and damp air.
Yes, any change to line length or reconnection needs a fresh pressure test from the inlet point. We stress not to cut or reseal the line yourself, because opening and re-closing wrongly can admit air and drop pressure. Call us to do the work and run the full test again.