Copper or steel pipe run
Correct diameter pipe sized to kitchen appliance load and inlet pressure.

Ahmadi
Kitchen gas piping in Fahad Al-Ahmad starts from the inlet point at the outer wall and runs to the cooktop, oven and water heater. We test every joint with soapy water and pressure, then confirm no leaks before handover.
In Fahad Al-Ahmad family homes, kitchens often open onto the living area, so the gas line must run hidden in walls or under floors. We measure from the inlet and pick the shortest route that avoids load-bearing columns. If the line must cross an outer wall, we drill the right size hole and pass the pipe through a steel protective sleeve.
Fahad Al-Ahmad sits in Ahmadi governorate, a planned residential district of family villas with modern kitchens.
We pressure-test every new gas line at 10 bar for ten minutes because the new section must hold pressure before use.
Correct diameter pipe sized to kitchen appliance load and inlet pressure.
Individual outlet with isolation valve for each hob, oven or fryer.
Pipe run inside protective conduit or channel with ventilation clearance observed.
Joints finished by brazing or press-fit method suited to the pipe material.
Nitrogen pumped to test pressure and held to confirm every joint is tight.
Inspection of an existing run and repair of any corroded section or weeping joint.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, we use copper or galvanised steel pipe per code and fix it in a straight channel with metal supports. We leave extra length at the oven end for easy disconnection during servicing.
We apply soapy solution to every joint and pipe length under 10 bar pressure. No bubbles mean zero gas escape at any point.