Copper or steel pipe run
Correct diameter pipe sized to kitchen appliance load and inlet pressure.

Mubarak Al-Kabeer
Gas installation in Funaitees serves residential villas and family homes from the government inlet to family kitchens. We run pipes through gardens and outdoor spaces with care, testing all pressure and joints before any cooker is lit.
Funaitees houses are tightly spaced on medium-sized plots, each with a front garden and rear yard. Sometimes we run the pipe through the rear courtyard to avoid digging under the front garden and landscaping. Gas pipes are fixed to external walls or buried protected in plastic ducts underground. Both cooker and electric heater usually sit close to the inlet point.
Funaitees sits near Mubarak Al-Kabeer governorate and comprises family homes at moderate residential density.
Every pipe is cleared of internal dust and moisture before connection to cooker to prevent nozzle blockage.
Correct diameter pipe sized to kitchen appliance load and inlet pressure.
Individual outlet with isolation valve for each hob, oven or fryer.
Pipe run inside protective conduit or channel with ventilation clearance observed.
Joints finished by brazing or press-fit method suited to the pipe material.
Nitrogen pumped to test pressure and held to confirm every joint is tight.
Inspection of an existing run and repair of any corroded section or weeping joint.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, but we recommend burying them in plastic ducts to protect from damage if you dig later. Minimum depth is one metre and we place a warning tape six inches above.
We leave a short easy-disconnect coupling at the current cooker location so you can connect a new cooker elsewhere later. Extra pipe length is neatly coiled behind the new cooker position.