Main pipe run
Running the supply line into the kitchen at the correct pipe diameter

Jahra
Your Naeem restaurant gas network needs safe routing from the outdoor cylinder through calibrated copper pipes to every appliance. We position the cylinder away from sun and heat and choose pipe diameter by distance and pressure requirement. Every joint is pressure-tested with compressed air before operation.
Naeem restaurants occupy both old and new residential buildings, some without proper kitchen facilities needing major structural adaptations. We measure available space between the outdoor cylinder and kitchen, then choose between wall-mounted overhead runs or ground-level protective ducts. Where space is tight we use spiral-wrap flexible pipes instead of costly rigid sections.
Naeem is a mixed residential district in Jahra governorate where small food shops share buildings with residential families.
At completion we open the main regulator valve and watch the pressure gauge for thirty seconds to confirm no rapid drop occurs.
Running the supply line into the kitchen at the correct pipe diameter
Dedicated branch for each burner, oven, grill or fryer in the kitchen
Valve at each appliance so one unit can be isolated without stopping the whole line
Pipes run inside the wall or surface-mounted to suit the building structure
Completed network tested under dry nitrogen pressure before any appliance is connected
Inspecting or extending a working kitchen gas network with minimal downtime
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes if the wall is strong enough, but we fit a protective metal backing plate and a brass lock bracket. The cylinder must be raised and shaded, away from direct heat and sunlight.
We use larger-diameter pipes to offset pressure loss over the long run and may fit an additional regulator midway. The heavier pipe and extra regulator maintain flame quality and consistent performance.
