Main pipe run
Running the supply line into the kitchen at the correct pipe diameter

Capital
Installing your restaurant gas network in Qortuba starts by routing copper tube from the inlet through the kitchen to each appliance. We size each pipe section for total gas load and run distance, support all runs with steel brackets and test pressure and leaks with certified gauges.
Qortuba's upscale villas have spacious standalone kitchens with a separate service entrance. We run gas piping hidden behind the kitchen's outer walls or under the floor slab where the structure allows, because visible copper in an upmarket setting affects appearance. We wrap PTFE tape around every solder joint and at each valve inlet before sealing with flux and solder.
Qortuba lies in Kuwait governorate and holds upscale residential villas near جمعية قرطبة التعاونية.
Before handover the network is pressurized with inert gas and held for one hour because any pressure drop signals a leak that must be found.
Running the supply line into the kitchen at the correct pipe diameter
Dedicated branch for each burner, oven, grill or fryer in the kitchen
Valve at each appliance so one unit can be isolated without stopping the whole line
Pipes run inside the wall or surface-mounted to suit the building structure
Completed network tested under dry nitrogen pressure before any appliance is connected
Inspecting or extending a working kitchen gas network with minimal downtime
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Behind the kitchen's outer walls if there is enough space between inner and outer layers. If walls are too thin we run pipes under the floor slab or mount them on the outer wall in covered steel conduit.
We wrap PTFE tape on the thread of every soldered joint and then test with leak detection liquid after cooling. Any bubble means a weak joint that must be reheated and resoldered.