Hot and cold supply points
PPR lines routed precisely to basin, shower and toilet positions

Ahmadi
Bathroom rough-in at Zour starts by measuring roof-tank height and drainage path from adjacent central cooling units. We run protected supply and waste through areas warmed by power plant heat and pressure-test every run.
Zour installations are massive power and desalination plants with cooling towers and extremely tight engineering voids between equipment. Supply pipes need thermal insulation because steam lines nearby raise temperatures, and waste must drop quickly through congested areas packed with joints and supports. Near the main Zour plants sit operations staff accommodation, and every bathroom there needs robust pipes that withstand vibration and sustained heat.
Zour sits in Ahmadi governorate near the power generation plant, an industrial zone of high heat and constant humidity.
We test pipe heat resistance before handover and log temperatures at each point because failure later will halt operations.
PPR lines routed precisely to basin, shower and toilet positions
uPVC drain runs laid at correct fall to prevent standing water
Floor trap levels set before screed to align flush with final tiling
Connecting the waste run to the vent stack prevents trap siphoning and odour
Documented pressure test on supply lines before walls are permanently closed
All supply and waste point locations recorded for finishing and future maintenance
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, because of nearby steam lines and hot equipment. Insulation keeps water temperature stable and prevents excessive thermal expansion.
We secure all pipes on flexible supports, not rigid, and use flex couplings at critical junctions. Constant vibration cracks solid joints quickly.