Hot and cold supply
PPR runs sized for sink, dishwasher and fridge-water connections

Capital
Kitchen first fix in Gharnata manages deep foundations and thick concrete slabs in outer suburban areas. We trace pipe routes precisely before concrete is poured and test every joint under strong air pressure.
Modern Gharnata houses sit on deep footings with multiple waterproof layers and long pipe runs from the external meter. Kitchens are usually spacious with one or two sinks and sometimes an island cooktop. We specify copper for the supply because the run is long, and install an isolation valve at entry for fast shutoff during maintenance. Waste needs larger diameter because the slab sits slightly below sea level in some plots.
Gharnata sits in Kuwait governorate in the outer suburbs where houses spread further from the centre.
We mark foundation depth and stack position on a plan before work starts because thick concrete makes drilling holes afterward difficult.
PPR runs sized for sink, dishwasher and fridge-water connections
uPVC drain at correct fall to stop grease settling inside the pipe
Grease trap position and vent stack stub to block sewer odour entry
Gas supply stub-out to cooker position run before wall cladding closes
Supply and drain stub prepared at the right height for the water heater
Recorded pressure test on all supply lines before any wall is closed
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
We use three-quarter inch or larger copper to cut pressure loss over the long distance. We clip it to metal supports under the slab and install an isolation valve near the sink for servicing.
Yes, we fill the line with water for an hour and check every joint for leaks. It takes time but prevents catastrophic failure under concrete days later.