Site and drain check
Measure the bay and confirm drain fall before moving the unit

Farwaniya
Jacuzzi installation in Rehab starts by routing supply from the roof tank and checking waste slope to the floor drain. We test the jet pump, fit the pipework, support the basin with concrete bedding and run a full test before handover.
Rehab houses mostly have large master bathrooms with sloped floors toward a floor trap, which lets us fit a jacuzzi without raising the level. We check the trap depth and floor gradient because the jacuzzi needs a steady fall from basin to waste without blockage. The supply line comes from the roof tank and runs through existing wall pipes or under fresh tiles.
Rehab sits in Farwaniya governorate, a residential zone where detached family villas have open courtyards between them.
The jacuzzi runs for five full minutes with all jets active to verify water drains without leaks from the basin or pump.
Measure the bay and confirm drain fall before moving the unit
Set the unit level so water drains fully without pooling
Hot and cold lines connected with accessible isolation valves
Deep-seal trap sized to the unit outlet, preventing drain odour
Verify pump connection point and electrical outlet with the electrician
Sanitary silicone on all edges, full water test before handover
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
We measure the pipe diameter and pressure at the tap first. If pressure drops when jets run, we enlarge the main supply line or run a separate feed for the jacuzzi.
Usually no, if the floor trap is close and deep enough. We measure the fall and plan the waste route so the basin stays level with the existing floor.