Frame and tray level
Frame and tray set perfectly flat so water drains fully

Jahra
Shower cabin fitting on the Mutlaa ridge requires managing extremely high temperatures and sharp daily swings in expansion and contraction. We secure the frame with slightly flexible bolts and very elastic sealant, then test the drain with alternating hot and cold water.
Bathrooms on Mutlaa ridge are exposed to direct sun most hours, and tile walls and the aluminium frame expand fast at noon and contract fast at sunset. Rigid silicone will crack in one month from repeated expansion and contraction. We use high-grade silicone that stays elastic even in extreme heat, and leave a small gap between frame and side wall to absorb movement. Aluminium bolts shrink less than steel, but we leave them slightly loose rather than tight.
Mutlaa is a high desert ridge in northern Jahra where temperatures exceed fifty degrees Celsius daily.
Sealant is tested by spraying the frame with very hot water then cold water to simulate rapid daily temperature changes.
Frame and tray set perfectly flat so water drains fully
Trap connected to waste line at the correct fall
Flexible supply lines connected to isolation valve and shower outlet
Sanitary silicone applied along every profile edge and corner
Door magnets and hinges adjusted so the panel closes firmly
Water run, drain checked, all edges inspected for leaks
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Standard silicone loses elasticity above forty degrees and cracks when stretched. We use advanced synthetic silicone that stays flexible to sixty degrees and tolerates hundreds of expansion and contraction cycles.
Yes, we leave three millimetres between frame and side wall to absorb expansion movement, whereas tight gaps restrict movement and split sealant. This gap is filled with elastic silicone that permits movement.