Waste outlet check
Height and position confirmed before the shower tray is set.

Jahra
Mutlaa shower installation is set at a height matching the natural land slope in this elevated area. We check foundation stability and test lines under high pressure because elevation affects flow strength. We flood the enclosure and base, confirming the drain leaves no moisture beneath the floor before finish.
Mutlaa houses sit on a natural slope with varying foundation heights. This means shower supply pressure may be higher than in low areas, requiring a pressure regulator in the mixer. Drainage benefits from natural land slope, but metal pipes rust faster here due to temperature swings, so we choose strong plastic pipes instead.
Mutlaa is a high natural ridge in Jahra where houses spread across slopes of varying height and wind exposure.
We measure pressure at the shower head immediately after installation and record it visually because high pressure causes joint leaks over time.
Height and position confirmed before the shower tray is set.
Tray levelled and trap sealed with a rubber gasket.
Hot and cold lines connected to the mixer with isolation valves.
Mixer and arm fitted with thread sealant on every joint.
All tray-to-wall edges sealed with non-fungal sanitary silicone.
Water run and full drainage confirmed before handover.
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Actually the opposite here, elevation increases pressure if the tank sits higher than the head. But long lines from the tank cause pressure loss, so we measure actual pressure and fit a regulator if it exceeds safe limits.
Winds do not cause leaks but they pull water sideways during use. Shower enclosure design and wall height protect against this, but we ensure the base seals with high-grade moisture barrier.
