Concealed frame fitting
Steel carrier frame anchored at the specified height inside the wall

Capital
Wall-hung toilet installation in Qortuba starts with anchoring a steel frame firmly inside the wall before tiling over it. We run supply and waste pipes through the wall cavity, fit the concealed cistern and bowl, then pressure-test everything before leaving.
In the upscale villas near Qortuba Co-op, bathrooms are often tight on space and families want the clean look of a concealed cistern. The wall-hung frame delivers that, but we measure wall depth first to check there is room for pipes and the tank behind it. Where the wall is thin we fit a shallow frame, and where the floor slab is sound with no damaged pipes we run the waste straight from the base.
Qortuba is in Kuwait governorate and consists of family villas where the wall-hung toilet is the first choice for main bathrooms.
We pressure-test every joint at 10 bar for ten minutes before the job is handed over.
Steel carrier frame anchored at the specified height inside the wall
Waste pipe set at the correct fall to prevent backflow and odour
Supply line connected with an accessible isolation valve behind the service panel
Flush volume and fill valve pressure adjusted to stop continuous water loss
Bowl hung on frame studs with correct bolts and seat fitted firmly
Full leak check before wall is closed and again after cladding is in place
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, but wall thickness must be measured first to choose a frame of suitable depth. Modern frames 10 cm deep suit thin walls and carry the load safely.
Waste descends through the wall from the bowl base, then bends at floor level toward the main drain stack. We use 110 mm PVC pipe with a steady fall to ensure free drainage.
