Crack mapping by camera
Internal camera maps every crack and its depth before work begins

Jahra
Tank repair in Kabd starts by checking the base and mounts because pump and generator vibration causes cracks in the bottom. We locate the crack and treat every weak bond. The tank is pressure-tested with water before we move on.
Kabd properties often have engines, generators and fibreglass tanks on the roofs of nurseries, holding barns and homes. Constant vibration from these machines travels to the tank through its mounts and stresses the base and lower sides. Cracks start at the base corners where stress peaks. We lift the tank carefully and check every support point and look for resin stress marks and hairline cracks around the bolt holes.
Kabd sits in Jahra governorate near the racing circuit, a rural and farm area where heavy machines and pumps run constantly.
We check every tank bolt joint with a torque wrench before refilling to prevent vibration leaks.
Internal camera maps every crack and its depth before work begins
Grinding the area around the crack ensures the resin bonds properly
Resin-saturated glass-mat layers fill the crack and restore structural stiffness
Delaminated sections are removed and rebuilt with matching laminate material
Full interior coat with epoxy rated safe for potable water contact
Camera confirms no remaining cracks or coating bubbles before the tank refills
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes, if the tank is lifted gently but knocked during moving, cracks can show immediately or days later. We inspect the whole tank before remounting and test it under water pressure.
In many cases yes. We move the tank away from the pump or add vibration dampers under the base. But if the problem is severe we may suggest a stronger tank or fewer machine operating hours.