Inspection and mapping
Internal camera maps every crack and spalled area before work starts

Farwaniya
Tank repair in Ishbiliya requires checking the concrete base and detecting fine cracks and point leaks. We seal cracks with liquid epoxy injection then coat the inner surface with a water-resistant sealant layer.
Most Ishbiliya tanks are concrete poured on flat roofs and face expansion and contraction from seasonal temperature swings. We inspect joints between floor and walls and around the floor drain opening. If we find a small crack we trace its path before deciding between injection or partial rebuilding.
Ishbiliya is a relatively modern residential district in Farwaniya governorate with most homes built in the 1990s and concrete tanks prone to thermal cracking.
After epoxy injection, cracks are tested by spraying water from outside and inspecting inside to confirm complete sealing.
Internal camera maps every crack and spalled area before work starts
All scale, efflorescence and loose material removed before any filler is applied
Hydraulic mortar seals active and dry cracks in concrete walls and floor
Repair render restores corroded or pitted wall surfaces to a uniform face
Drinking-water rated coating applied over fully cured and prepared surfaces only
Camera confirms coating integrity and joint sealing before the tank refills
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Hairline cracks that do not widen cause only slow seepage and are fixed by epoxy injection. Large expanding or moving cracks need partial rebuilding or full replacement.
Yes, thermal expansion causes hairline cracks after many years. Reflective coating and good ventilation around the tank reduce impact, but annual inspection catches problems early.