Acoustic surface scan
Tracing the leak sound through tile and screed layers

Mubarak Al-Kabeer
Leak detection under tiles in Sabah Al-Salem requires sensitive equipment because the subdivision homes are new and fresh pipes may leak without visible signs. We trace the pipe and test it with compressed air before any digging decision.
New homes in Sabah Al-Salem were built to code with tile floors bonded to a smooth concrete bed. When slight leakage appears around a sink we begin tracing the copper or polyethylene pipe beneath the floor using a radio tracer. We measure tile and bed thickness and determine if the leak is at a joint or in the pipe body before opening any hole.
Sabah Al-Salem in Mubarak Al-Kabeer sits near Messila Park, a modern residential area where pipes run hidden beneath fully bonded tile.
We test new pipes at 5 bar air pressure for ten minutes because minute joint leaks do not show under static water pressure.
Tracing the leak sound through tile and screed layers
Isolating the suspect line and measuring pressure drop to confirm fault location
Filming inside the pipe from the nearest access point to view the crack
Marking the exact spot on the tile surface to minimise breaking area
Checking pipe branches hidden inside the adjacent ceiling or wall
Handing the confirmed location directly to the repair team
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
A leak under fully bonded tile is invisible and usually silent. You may spot a slowly growing wet patch or notice a musty smell after weeks. The detector is the only certain way.
No, we pull the pipe only from the leaking joint to the next secure junction. We splice in a new section of the same diameter and material in the same run and test it with air before closing the tile.