Live pressure reading
Measuring cut-in and cut-out values before touching anything

Mubarak Al-Kabeer
Pump pressure switch repair in Qurain often begins with a pump that clicks on and off every few seconds. That rapid cycling usually means the expansion vessel has lost its air charge, so we test the vessel before blaming the switch itself.
A Qurain villa with a ground tank and a small pressure vessel depends on the air cushion inside that vessel to smooth out demand. When the membrane fails or the air leaks away, every tap opening sends the pressure straight to cut-out and back, and the switch contacts wear quickly. We drain the vessel, measure its pre-charge, recharge or replace it, and then set the switch to match.
Qurain is a Mubarak Al-Kabeer residential area where many villas pump from a ground tank through a small pressure vessel.
A pump that restarts every few seconds with one tap open points to the vessel before the switch.
Measuring cut-in and cut-out values before touching anything
Testing the air bladder charge and refilling it if pressure is lost
Cleaning contacts or fitting a new switch matched to pump capacity
Calibrating both thresholds precisely to prevent rapid on-off cycling
Inspecting wiring and terminal resistance at both switch contacts
Running the pump and confirming stable pressure through a full cycle
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
Yes. Each start heats the motor and burns the switch contacts a little. Left for weeks, it can end in a failed switch or a burnt motor winding.
With the pump off and the taps drained, knock on the upper half of the vessel. A hollow sound suggests air is present. A dull, heavy sound suggests it is full of water and needs recharging.