Live pressure reading
Measuring cut-in and cut-out values before touching anything

Farwaniya
Pump pressure switch repair in Rehab begins by reading the tank gauge and checking the supply pipes. We test the cut-in and cut-out points and adjust the valve until pressure stabilizes at the right setting.
Rehab homes rely on ground tanks and roof-level distribution, and uneven pressure means the air cell inside the tank is not working properly. We open the tank cover and check the diaphragm and springs, then measure the air pressure in the upper chamber because moisture in the air causes pressure to drop over time. If the diaphragm is torn we replace it before recalibrating the pressure.
Rehab sits in Farwaniya governorate, a residential zone where each building has its own tank on the roof.
We take three consecutive pressure readings because humid air causes measurement drift.
Measuring cut-in and cut-out values before touching anything
Testing the air bladder charge and refilling it if pressure is lost
Cleaning contacts or fitting a new switch matched to pump capacity
Calibrating both thresholds precisely to prevent rapid on-off cycling
Inspecting wiring and terminal resistance at both switch contacts
Running the pump and confirming stable pressure through a full cycle
How we work

Tell us what is happening and where, and the right equipment is loaded before we arrive.

We film the line from inside and know the kind of blockage and its exact place. No guessing.

High pressure water, a machine or a drain snake, whichever the line actually needs.

The camera runs a second pass and you see the line clear with your own eyes before we leave.
Same method, same equipment. Only the size of the job changes.




Why us
Amana means trust. Someone else's home is not ours to be careless in.
Do not take our word for it. Look at the line yourself.
Breaking is the last resort, never the first step.
A blocked line does not wait for the morning.
Six governorates, 139 areas.
For buildings and complexes, servicing before the problem starts.
Restaurants, offices and complexes, not only homes.
Common questions
Need someone now? The emergency line is open any hour.
+965 9668 4964
The air inside the tank loses pressure over time due to moisture and tiny leaks. We check the diaphragm first, and if it is intact we pump extra air into the upper chamber.
Yes, close the main valve and open a tap near the tank to bleed pressure. Then open the cover slowly because any remaining pressure can spray water.